Users Online : 673 About us |  Subscribe |  e-Alerts  | Feedback | Login   
Journal of Minimal Access Surgery Current Issue | Archives | Ahead Of Print Journal of Minimal Access Surgery
           Print this page Email this page   Small font sizeDefault font sizeIncrease font size 
 ¤   Next article
 ¤   Previous article
 ¤   Table of Contents

 ¤   Similar in PUBMED
 ¤  Search Pubmed for
 ¤  Search in Google Scholar for
 ¤Related articles
 ¤   Citation Manager
 ¤   Access Statistics
 ¤   Reader Comments
 ¤   Email Alert *
 ¤   Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1555    
    Printed46    
    Emailed0    
    PDF Downloaded146    
    Comments [Add]    

Recommend this journal

 

 ORIGINAL ARTICLE
Year : 2013  |  Volume : 9  |  Issue : 4  |  Page : 159-162

Trocarless laparoscopic pyloromyotomy with conventional instruments: Our experience


Department of Pediatric Surgery, KEM Hospital, Parel, Mumbai, India

Correspondence Address:
Pooja V Multani
Department of Pediatric Surgery, Old Building, King Edward Memorial Hospital, Parel - 400012, Mumbai
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0972-9941.118831

Rights and Permissions

Background: The incidence of hypertrophic pyloric stenosis is approximately 1-3 per 1,000 live births. Hypertrophic pyloric stenosis is seen more often in males, with a male-to female ratio of 4:1. Laparoscopic pyloromyotomy is becoming increasingly popular as the standard treatment for hypertrophic pyloric stenosis. Materials and Methods: We describe our initial experience with laparoscopic pyloromyotomy in 16 infants using conventional laparoscopic instruments. Laparoscopic pyloromyotomy was performed through 5-mm umbilical port with 5mm 30 endoscope. Two 3-mm working instruments were inserted directly into the abdomen via separate lateral incisions. Results: All patients were prospectively evaluated. The procedure was performed in 16 infants with a mean age of 36 days and mean weight of 3.1 kg. All procedures, except two, were completed laparoscopically with standard instruments. Average operating time was 28 mins, and average postoperative length of stay was 2.8 days. There were no major intraoperative and postoperative complications. Conclusion: Laparoscopic pyloromyotomy can be safely performed by using standard conventional laparoscopic trocarless instruments.






[FULL TEXT] [PDF]*


        
Print this article     Email this article

© 2004 Journal of Minimal Access Surgery
Published by Wolters Kluwer - Medknow
Online since 15th August '04