Users Online : 280 About us |  Subscribe |  e-Alerts  | Feedback | Login   
Journal of Minimal Access Surgery Current Issue | Archives | Ahead Of Print Journal of Minimal Access Surgery
           Print this page Email this page   Small font sizeDefault font sizeIncrease font size 
  Search
 
 ¤  Next article
 ¤  Previous article 
 ¤  Table of Contents
  
 ¤   Similar in PUBMED
 ¤  Search Pubmed for
 ¤  Search in Google Scholar for
 ¤Related articles
 ¤   Article in PDF (613 KB)
 ¤   Citation Manager
 ¤   Access Statistics
 ¤   Reader Comments
 ¤   Email Alert *
 ¤   Add to My List *
* Registration required (free)  


 ¤  Abstract
 ¤  Introduction
 ¤  Case Report
 ¤  Discussion
 ¤  References
 ¤  Article Figures

 Article Access Statistics
    Viewed2427    
    Printed157    
    Emailed1    
    PDF Downloaded205    
    Comments [Add]    
    Cited by others 1    

Recommend this journal

 


 
UNUSUAL CASE
Year : 2009  |  Volume : 5  |  Issue : 2  |  Page : 40-42
 

Colonoscopic retrieval of migrated copper-T


1 Department of Surgery, NEIGRIHMS, Shillong, India
2 Departments of Obstetrics & Gynecology, NEIGRIHMS, Shillong, India

Date of Submission24-Sep-2008
Date of Acceptance11-Dec-2008
Date of Web Publication20-Aug-2009

Correspondence Address:
Laleng M Darlong
Department of Surgery, NEIGRIHMS Shillong
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0972-9941.55107

Rights and Permissions

 ¤ Abstract 

Intrauterine contraceptive devices have been in use for a long time as family planning measures, one of its complications of perforating the uterus and migrating into the peritoneal cavity is also well known. Retrieval in such cases depends on the location of the migrated intrauterine devices and involves laparotomy or laparoscopy. We present here such a case that migrated partially into the lumen of the rectosigmoid and was successfully removed using a colonoscope.


Keywords: Colonoscopy, migrated Cu-T


How to cite this article:
Darlong LM, Panda S, Topno N, Hajong R. Colonoscopic retrieval of migrated copper-T. J Min Access Surg 2009;5:40-2

How to cite this URL:
Darlong LM, Panda S, Topno N, Hajong R. Colonoscopic retrieval of migrated copper-T. J Min Access Surg [serial online] 2009 [cited 2019 Oct 18];5:40-2. Available from: http://www.journalofmas.com/text.asp?2009/5/2/40/55107



 ¤ Introduction Top


Intrauterine contraceptive device (IUCD) has been in vogue since 1965 [1] for the purpose of contraception. Perforation of the uterus is not infrequent and occurs in 1/350-1/2500 insertions. Perforation leads to migration of the device to the organs to which the uterus is intimately related, such as the bladder and the rectosigmoid. Perforation may occur during the act of insertion or at a later date. Perforation during insertion is directly related to the experience and skill of the clinician. We report a case of IUCD which had perforated partly into the rectosigmoid and partly lying in the pelvic cavity, which was successfully removed using a colonoscope.


 ¤ Case Report Top


A 25-year-old women; Para 2 and abortion 1 presented to the Obstetrics and Gynecology OPD with a history of a copper T insertion in January 2004. Since December 2004, she could not feel the thread. She had a history of missed period and consulted a local gynecologist. Pregnancy was confirmed and a MTP was done for the unwanted pregnancy. During the MTP, IUCD was not found in the uterine cavity. At this point, the patient was referred to our center for further management.

She complained of constant backache and pain during defecation.

Clinical examination revealed tenderness in the lower abdomen on deep palpation, no rebound tenderness, no free fluid; P/V: tenderness in the posterior fornix. P/R: mild tenderness was elicited. Pelvic X-ray showed the IUCD lying outside the uterus [Figure 1]. USG pelvis did not reveal the device. CT of the abdomen and pelvis was planned which revealed the copper T device partly in the rectosigmoid and partly in the pelvis [Figure 2]. She also had minimal free fluid in the pelvis. Hb%, total leucocyte counts and other investigations were within normal range. Necessary consent was obtained for colonoscopy and possible laparotomy. Colonoscopy was done under sedation with injection of midazolam and pethidine to assess the possibility of extraction of the device. Colonoscopy showed a part of the limb of T device as in [Figure 3]. It was decided that colonoscopic extraction would be attempted failing which a laprotomy was planned. Prophylactically, she was started on injection of piperacillin-tazobactum and metronidazole. Using a biopsy forceps, the "T" end of the device was pulled into the rectosigmoid. The forceps was replaced with a snare and one limb of the "T" was secured and the device extracted through the anal opening. The recto sigmoid area was inspected and no bleeding found.

Postprocedure the patient was fine, transferred to the ward for observation. Her abdomen was soft. The patient was kept nil per oral for 24 hours and started on fluids, and was taking normal diet after 48 hours postprocedure. Antibiotics were continued for 3 days, with the patient passing stools normally and tolerating orally she was discharged on oral cefaclor 500 mg bid for five more days. The patient was followed up after 1 week, and lower abdomen pain had subsided and she had no more painful defecation


 ¤ Discussion Top


IUCD is generally a safe mode of long-term contraception. Associated complications are bleeding, infection, ectopic pregnancy and uterine perforation. The latter is one of the most morbid complications. The perforation is thought to occur at the time of insertion or occur due to chronic inflammatory reaction to the copper-containing foreign object leading to gradual erosion through the uterine wall. It is probable that of the various factors responsible for uterine perforation by IUDs, the most important are consistency and flexion of the uterus, the type and rigidity of the IUDs and its inserters and the amount of force exerted at insertions with the result that the IUDs stops at certain points rather than proceeding to complete perforation. [2] A majority of the perforations occur during the time of insertion. The delayed onset of symptoms usually means migration of the device. Timing of IUCD insertion is flexible. Most important, women who were lactating at the time of IUD insertion were 10 times as likely to have had a uterine perforation as women with at least one live birth, but who were not lactating at the time of insertion. [1]

In this case, the possible mechanism of IUCD migration is gradual erosion of the uterine wall due to chronic inflammation. Patients with indwelling IUCD should be always alerted about the possibility of its migration; regular self-examination for missing thread is useful in early detection of migration.

A plain radiograph of the abdomen and pelvis is taken to rule out unnoticed expulsion of the IUCD or USG. CT scan is recommended for exact location of the device. [3] Treatment of migrated IUCD is mostly surgical, either laparoscopic or laparotomy. In partial migration of the device, when, asymptomatic the recommendation is to withdraw it. This avoids future complications like bowel perforation, bladder perforation and fistula formation. There are few reports where the migration has been into the rectosigmoid and the pelvis where the extraction of the device has been done manually per rectum and also using a sigmoidoscope or colonoscope. [4],[5],[6] The patients did not develop peritonitis after removal. It is likely that a contained pericolic abscess may have formed already due to the longstanding nature of this case thus preventing any feacal leak and resultant peritonitis.

 
 ¤ References Top

1.Heartwell SF, Schlesselman S. Risk of uterine perforation among users of intrauterine devices. Obstet Gynecol 1983;61:31-6.  Back to cited text no. 1  [PUBMED]  
2.Zakin D, Stern WZ, Rosenblatt R. Complete and partial uterine perforation and embedding following insertion of intrauterine devices. Obstet Gynaecol Surg 1981;36:335-53.  Back to cited text no. 2    
3.Richardson ML, Kinard RE, Watters DH. Loation of intrauterine devices: evaluation by computed tomography. Radiology 1982;142:690.  Back to cited text no. 3  [PUBMED]  [FULLTEXT]
4.Assarian A, Raja MA. Colonoscopic retrieval of a lost intrauterine contraceptive device: A case report and review of articles. Eur J Contracept Reprod Health Care 2005;10:261-5.  Back to cited text no. 4  [PUBMED]  [FULLTEXT]
5.Sepúlveda WH. Perforation of the rectum by a Copper-T intra-uterine contraceptive device; a case report. Eur J Obstet Gynecol Reprod Biol 1990;35:275-8.  Back to cited text no. 5    
6.Bromham DR, Firth GM,Fothergill DJ. Sigmoidoscopic recovery of a displaced intra-uterine device. Br J Fam Plann 1984;9:125-7.  Back to cited text no. 6    


    Figures

  [Figure 1], [Figure 2], [Figure 3]

This article has been cited by
1 Mystery of the missing loop
RS Bharathi, A Chakladar, P Kumari
Medical Journal Armed Forces India. 2011; 67(2): 177
[VIEW] | [DOI]



 

Top
Print this article  Email this article
Previous article Next article

    

© 2004 Journal of Minimal Access Surgery
Published by Wolters Kluwer - Medknow
Online since 15th August '04